Experiment 02: Verification of Kirchhoff’s Current and Voltage Laws
Student lab-note template · Verify the experiment order and circuit diagram against your department's current lab manual.
1. Objective
To study and experimentally verify experiment 02: verification of kirchhoff’s current and voltage laws using instructor-approved apparatus and measured observations.
Kirchhoff’s Current Law (KCL): the algebraic sum of currents at a node is zero; total current entering equals total current leaving. Kirchhoff’s Voltage Law (KVL): the algebraic sum of voltage rises and drops around a closed loop is zero. These laws follow from conservation of charge and energy.
3. Apparatus
Use the apparatus specified by your instructor and the actual circuit diagram supplied in the lab. Typical items may include a regulated low-voltage DC supply or signal generator, breadboard/trainer board, appropriate resistors/components, connecting leads and correctly ranged meters. Check every component's rating before energizing the circuit.
4. Circuit diagram
Insert or draw the exact circuit from your current lab manual here. Label component values, polarities, meter positions, source settings and current directions. Do not treat a generic diagram as a substitute for the instructor's circuit.
5. Procedure
Build a low-voltage resistive network using the circuit diagram supplied by the instructor. Measure branch currents with the ammeter in series with each branch and node/element voltages with the voltmeter in parallel. Record current directions and voltage polarities before taking readings. For KCL, compare the sum entering a node with the sum leaving. For KVL, add signed voltage rises and drops around a loop.
6. Observation table
| Test | Measured quantities | Check |
|---|---|---|
| KCL at node A | I₁ = ; I₂ = ; I₃ = | I₁ ≈ I₂ + I₃ |
| KVL, loop 1 | V₁ = ; V₂ = ; V₃ = | V₁ − V₂ − V₃ ≈ 0 |
7. Calculations
KCL error (%) = |Iin − Iout|/Iin × 100, where Iin is non-zero. KVL residual = algebraic sum of measured loop voltages. State chosen signs clearly.
8. Result and discussion
Small residuals are expected because of resistor tolerance, meter loading, lead resistance and reading uncertainty. A large mismatch often indicates incorrect polarity, wiring or meter connection.
9. Precautions
- Switch off the supply before wiring or changing connections.
- Check polarity, meter mode, range and component ratings before switching on.
- Use current limiting and begin with the lowest practical source setting.
- Never connect an ammeter in parallel with a source; never short an unknown source.
- Record actual readings with units; do not fabricate observation values.
- Follow the instructor's bench-safety directions and the component datasheets.
10. Viva voce
- State KCL. 2. State KVL. 3. Which conservation principles underlie them? 4. How should an ammeter be connected? 5. What happens if an ammeter is connected in parallel?
Short answers
KCL is based on conservation of electric charge; KVL on conservation of energy in a lumped circuit. Never connect an ammeter directly across a voltage source; it can create a short circuit.
Academic integrity: This is a study/report template, not an official NU-issued experiment sheet. Fill in your own circuit diagram, actual readings, calculations and instructor-required format. The repository's experiment list is based on an older syllabus reference and must be checked against the current lab manual.