Chapter 05: Regulated Power Supply
Course: Electrical and Electronic Circuit (EEC) Course Code: 510203 Topic group: Regulated Power Supply
Most electronic circuits need a DC supply, but the electricity available from a wall outlet is AC. A regulated power supply converts AC into DC and keeps the output voltage reasonably steady even when the input supply or load changes.
This chapter connects several earlier topics: AC fundamentals, diodes, rectification and Zener regulation.
Learning outcomes
After studying this chapter, you should be able to:
- Explain the purpose and main stages of a regulated power supply.
- Define rectification, filtering, ripple and voltage regulation.
- Explain the operation of half-wave, full-wave centre-tapped and bridge rectifiers.
- Compare rectifier output waveforms and important quantities.
- Explain how a capacitor filter reduces ripple.
- Describe Zener diode and transistor voltage regulators.
- Solve introductory rectifier and regulator numericals.
1. What is a regulated power supply?
A regulated power supply is an electronic circuit that provides a stable DC output voltage from an electrical input, despite reasonable variations in input voltage or load current.
Why is regulation needed? Imagine a circuit designed to work at 5 V. If its supply rises or falls significantly, the circuit may malfunction or become damaged. A regulator helps keep the output within a suitable range.
Main stages of a basic DC power supply
A traditional linear power supply commonly has these stages:
- Transformer: changes the AC voltage to a suitable level and may provide isolation.
- Rectifier: converts AC into pulsating DC.
- Filter: reduces the fluctuations (ripple) in the rectifier output.
- Voltage regulator: maintains a more nearly constant DC output.
Simplified block diagram:
AC input
|
v
Transformer
|
v
Rectifier
|
v
Filter
|
v
Voltage regulator
|
v
Stable DC output
Some modern power supplies use switching converters rather than a traditional transformer-and-linear-regulator arrangement. The block diagram above describes the basic linear supply taught in introductory electronics.
2. Important terms
Rectification: The process of converting an alternating voltage or current into a unidirectional (one-direction) output.
Pulsating DC: A unidirectional voltage or current whose magnitude changes with time.
Filter: A circuit that reduces unwanted AC variations in a rectifier's output.
Ripple: The remaining periodic variation in the output after rectification and filtering.
Voltage regulation: The ability of a power supply to maintain its output voltage when input voltage or load conditions change.
Load: The circuit or device that receives power from the supply.
A rectifier output is called pulsating DC because its polarity does not reverse across the load, even though its magnitude rises and falls.
3. Half-wave rectifier
A half-wave rectifier uses one diode to pass one half-cycle of an AC input and block the other half-cycle.
Circuit idea
D
AC o───|>|─────+──── Vout(+)
|
R_L
|
AC o────────────+──── Vout(-)
Here \(R_L\) is the load resistance.
Working principle
Assume an ideal diode and a sinusoidal AC input.
Positive half-cycle:
- The diode becomes forward biased.
- It conducts current.
- A positive voltage appears across the load.
Negative half-cycle:
- The diode becomes reverse biased.
- It blocks current.
- The load voltage is approximately zero.
The output therefore contains only one half of each input cycle.
Output waveform (conceptual)
Input AC: /\\ /\\
_____/ \\____/ \\____
\\ / \\ /
\\/ \\/
Half-wave: /\\ /\\
_____/ \\____________/ \\____
The sketch is conceptual, not a scale drawing.
Important ideal half-wave formulas
Let \(V_m\) be the peak value of the sinusoidal input voltage across the rectifier.
Average (DC) output voltage:
RMS output voltage:
Ripple frequency:
Peak inverse voltage (PIV) of the ideal diode:
These standard results assume an ideal diode and a resistive load without a filter capacitor. A real diode's forward drop changes the output.
4. Full-wave rectifier
A full-wave rectifier uses both half-cycles of an AC input to produce a unidirectional output across the load.
There are two common arrangements:
- Centre-tapped full-wave rectifier.
- Bridge rectifier.
The output pulses occur during both positive and negative input half-cycles, so the ripple frequency is twice the input frequency.
4.1 Centre-tapped full-wave rectifier
This circuit uses a centre-tapped transformer and two diodes.
Simplified circuit idea:
Transformer end A ──|>|───+
D1 |
+──── Vout(+)
|
R_L
|
Centre tap ───────────────+──── Vout(-)
|
Transformer end B ──|>|───+
D2
The two secondary ends produce voltages of opposite phase with respect to the centre tap.
Positive half-cycle: One diode conducts and sends current through the load.
Negative half-cycle: The other diode conducts. The current through the load still flows in the same direction.
Thus both half-cycles contribute to the output.
For an ideal centre-tapped full-wave rectifier, let \(V_m\) represent the peak voltage of each half of the transformer secondary, measured from one end to the centre tap.
Average output voltage:
RMS output voltage:
Ripple frequency:
Peak inverse voltage of each diode:
Be careful: \(V_m\) here is the peak voltage of one half-secondary, not the peak voltage measured across the complete end-to-end secondary.
4.2 Bridge rectifier
A bridge rectifier uses four diodes arranged in a bridge. It does not require a centre-tapped transformer.
Simplified bridge arrangement:
D1 D2
AC terminal A o─|>|────+────|<|─o AC terminal B
|
(+) Vout
|
R_L
|
(-) Vout
|
AC terminal A o─|<|────+────|>|─o AC terminal B
D3 D4
This is a conceptual bridge sketch showing the four-diode arrangement. In an actual circuit, each half-cycle uses a diagonally opposite pair of diodes.
Positive half-cycle: One diagonal pair conducts.
Negative half-cycle: The other diagonal pair conducts.
Although the input polarity reverses, the current through the load remains in the same direction.
For an ideal bridge rectifier, where \(V_m\) is the peak voltage across the full transformer secondary:
In a practical bridge, two diodes are in the conducting path during each half-cycle. Therefore, the total forward drop is approximately twice the forward drop of one diode.
5. Comparison of rectifiers
The following comparison assumes ideal diodes, sinusoidal input and a resistive load without a filter capacitor.
| Feature | Half-wave | Full-wave centre-tapped | Bridge |
|---|---|---|---|
| Number of diodes | 1 | 2 | 4 |
| Uses input half-cycles | One | Both | Both |
| Average output | \(V_m/\pi\) | \(2V_m/\pi\) | \(2V_m/\pi\) |
| RMS output | \(V_m/2\) | \(V_m/\sqrt{2}\) | \(V_m/\sqrt{2}\) |
| Ripple frequency | \(f\) | \(2f\) | \(2f\) |
| PIV per diode | \(V_m\) | \(2V_m\) | \(V_m\) |
| Centre-tapped transformer | Not required | Required | Not required |
Important: In the centre-tapped column, \(V_m\) is the peak voltage of one half-secondary. In the bridge column, \(V_m\) is the peak voltage across the complete secondary. Do not compare the formulas without checking how the transformer voltage is defined.
Why is full-wave rectification generally better?
- It uses both half-cycles.
- Its average DC output is higher for the same relevant peak-voltage definition.
- Its ripple frequency is twice the AC supply frequency.
- Filtering is generally easier because the gaps between output pulses are shorter.
A bridge rectifier avoids the centre-tapped transformer requirement, but two diode drops occur in the conducting path.
6. Filter circuits and ripple reduction
A rectifier produces pulsating DC. Many electronic circuits need a smoother voltage. A filter circuit reduces the AC ripple component.
The simplest commonly taught filter is a capacitor connected in parallel with the load.
Capacitor filter
Rectifier output ────+──── Vout(+)
|
C
|
+──── GND
|
R_L
|
GND
The capacitor is connected across the load.
How does it work?
- As the rectifier output rises, the capacitor charges towards the peak voltage.
- When the rectifier output falls, the capacitor discharges slowly through the load.
- This discharge supplies the load between peaks.
- The output voltage therefore falls less sharply than the unfiltered rectifier output.
- The remaining small variation is called ripple voltage.
A larger capacitance or a lighter load (larger load resistance) generally reduces ripple, assuming other conditions remain the same.
Ripple frequency matters
- Half-wave rectifier: ripple frequency is \(f\).
- Full-wave rectifier: ripple frequency is \(2f\).
At the same supply frequency, a full-wave rectifier gives the capacitor more frequent charging opportunities, which generally makes smoothing easier.
Approximate capacitor-filter ripple formula
For a reasonably smoothed output, a common approximation is:
Where:
- \(V_{r(pp)}\) = approximate peak-to-peak ripple voltage (V)
- \(I_L\) = load current (A)
- \(f_r\) = ripple frequency (Hz)
- \(C\) = filter capacitance (F)
For a half-wave rectifier, \(f_r=f\). For a full-wave rectifier, \(f_r=2f\).
The approximation assumes the capacitor discharges relatively little between charging peaks. It is not an exact formula for every circuit.
Solved example 1: Capacitor filter ripple
A full-wave rectifier supplies a load current of 100 mA. The AC frequency is 50 Hz and the filter capacitor is 1000 µF. Estimate the peak-to-peak ripple voltage.
Step 1: Write the known values
- \(I_L = 100\text{ mA} = 0.1\text{ A}\)
- \(f = 50\text{ Hz}\)
- \(f_r = 2f = 100\text{ Hz}\)
- \(C = 1000\ \mu\text{F} = 0.001\text{ F}\)
Step 2: Apply the ripple formula
Answer: The estimated peak-to-peak ripple is approximately 1 V.
7. Voltage regulation
A rectifier and filter alone do not guarantee a constant output voltage. If the input voltage changes or the load draws more current, the output may change.
A voltage regulator is a circuit designed to maintain a nearly constant output voltage.
Percentage voltage regulation
One common definition of percentage load regulation is:
Where:
- \(V_{NL}\) = no-load output voltage
- \(V_{FL}\) = full-load output voltage
A smaller value generally indicates better load regulation under this definition.
Some textbooks use a different denominator or define regulation with respect to line variation. Always follow the definition stated in the question.
Solved example 2: Percentage load regulation
A supply gives 12.5 V at no load and 12 V at full load. Find percentage load regulation using the definition above.
Answer: Percentage load regulation is approximately 4.17%.
8. Zener diode voltage regulator
A Zener diode can be used as a simple shunt voltage regulator. It is connected in reverse bias across the load, while a series resistor limits current.
Circuit arrangement
R_S
Vin(+) ────/\\/\\/────+──── Vout(+)
|
┌──┴──┐
│ │
Zener R_L
(reverse │
bias) │
│ │
GND ──────────────+─────+──── Vout(-)
The Zener diode and load are connected in parallel.
Working principle
When the Zener operates in its breakdown region, the voltage across it remains approximately equal to \(V_Z\). Since the load is in parallel with the Zener:
The series resistor limits the current supplied from the source.
The current through the series resistor divides into Zener current and load current:
Using Ohm's law:
Load current:
Therefore:
For correct regulation, the Zener current must remain within the specified minimum and maximum operating limits. The Zener power must also remain below its rating:
Solved example 3: Zener regulator with a load
A 12 V input is connected to a 5.1 V Zener regulator through a 330 Ω series resistor. A 1 kΩ load is connected in parallel with the Zener. Assume the Zener is regulating. Find the series current, load current and Zener current.
Step 1: Find the series current
Step 2: Find the load current
Step 3: Find the Zener current
Answer:
- Series current \(\approx 20.91\text{ mA}\)
- Load current \(=5.1\text{ mA}\)
- Zener current \(\approx15.81\text{ mA}\)
The assumption that the Zener is regulating is valid only if this current lies within its specified operating range and its power rating is not exceeded.
9. Transistor voltage regulator
A transistor can be used as a series pass element to control the voltage delivered to a load. In a basic linear regulator, the transistor operates in its active region and adjusts its conduction to help keep the output voltage steady.
A reference voltage and a control or error-amplifier stage are often used to compare the output with the desired value and control the transistor.
Basic idea
Unregulated DC
|
v
Series pass transistor
|
+──────── Regulated DC output
|
Load
|
GND
Reference and feedback/control circuit
adjusts transistor conduction.
This is a functional block sketch, not a complete transistor-level circuit.
Working principle
- The unregulated DC supply is applied to the series pass transistor.
- The transistor controls how much voltage/current is delivered to the load.
- A reference and feedback circuit senses output changes.
- If output voltage tends to fall, the control circuit drives the transistor to conduct more.
- If output voltage tends to rise, the control circuit reduces conduction.
- The output is maintained approximately constant within the regulator's operating range.
Advantages
- Can provide better regulation than a simple unregulated rectifier-filter supply.
- Can supply more load current than a small Zener shunt regulator, depending on design.
- The output can be controlled using a reference and feedback circuit.
Limitations
- A linear pass transistor dissipates power as heat.
- A heat sink may be required.
- The input voltage must be sufficiently higher than the required output voltage.
- Efficiency is limited when the voltage difference across the pass element is large.
10. Zener regulator vs transistor regulator
| Feature | Zener regulator | Transistor series regulator |
|---|---|---|
| Main regulating element | Zener diode | Pass transistor with control/reference |
| Basic operation | Shunt regulation | Series regulation |
| Circuit complexity | Simple | More complex |
| Typical use | Simple, low-current regulation/reference | Higher load-current regulation, depending on design |
| Power loss | Zener and series-resistor losses | Pass-transistor dissipation |
| Control | Zener breakdown voltage | Feedback/control of transistor conduction |
11. Formula sheet
Half-wave rectifier (ideal, resistive load, no filter)
Full-wave rectifier (ideal, resistive load, no filter)
Ripple frequency
Capacitor-filter ripple approximation
Percentage load regulation
Zener regulator
Symbol meanings and units
- \(V_m\): peak input voltage (V)
- \(V_{DC}\): average/ DC output voltage (V)
- \(V_{RMS}\): root-mean-square output voltage (V)
- \(f\): input frequency (Hz)
- \(f_r\): ripple frequency (Hz)
- \(I_L\): load current (A)
- \(C\): capacitance (F)
- \(V_Z\): Zener voltage (V)
- \(R_S\): series resistance (Ω)
- \(R_L\): load resistance (Ω)
- \(P_Z\): Zener power (W)
12. Common mistakes to avoid
-
Mistake: A rectifier produces perfectly smooth DC. Correction: A basic rectifier produces pulsating DC. A filter reduces ripple.
-
Mistake: A half-wave rectifier uses both AC half-cycles. Correction: It uses one half-cycle; a full-wave rectifier uses both.
-
Mistake: Full-wave ripple frequency equals the input frequency. Correction: It is twice the input frequency.
-
Mistake: A bridge rectifier needs a centre-tapped transformer. Correction: A bridge rectifier does not require a centre tap.
-
Mistake: A larger capacitor always makes a supply perfect. Correction: It reduces ripple, but does not by itself provide precise voltage regulation. Inrush current, capacitor rating and regulator requirements also matter.
-
Mistake: In a Zener regulator, all series current flows through the Zener. Correction: Series current divides between the Zener and the load.
-
Mistake: Zener voltage regulation works at any current. Correction: The Zener must remain within its specified minimum/maximum current and power limits.
-
Mistake: A transistor regulator creates energy. Correction: It controls the voltage delivered from the input supply; a linear regulator dissipates some power as heat.
-
Mistake: \(V_m\) always means the same transformer voltage in every rectifier formula. Correction: Check whether it refers to one half-secondary or the complete secondary.
13. Exam-ready short answers
1. What is a regulated power supply? A regulated power supply is a circuit that provides a nearly constant DC output voltage despite reasonable changes in input voltage or load conditions.
2. What is rectification? Rectification is the process of converting AC into a unidirectional output.
3. What is a half-wave rectifier? A half-wave rectifier is a circuit that uses one diode to pass one half-cycle of an AC input and block the other half-cycle.
4. What is a full-wave rectifier? A full-wave rectifier is a circuit that uses both half-cycles of an AC input to produce a unidirectional output.
5. What is ripple? Ripple is the remaining periodic AC variation in the output of a rectifier after rectification and filtering.
6. What is a filter circuit? A filter circuit reduces the AC component or ripple in the rectifier output to produce smoother DC.
7. Why is the ripple frequency of a full-wave rectifier twice the input frequency? Because both positive and negative half-cycles produce output pulses, giving two pulses for each input cycle.
8. What is voltage regulation? Voltage regulation is the ability of a power supply to maintain a nearly constant output voltage when input or load conditions change.
9. What is a Zener regulator? A Zener regulator is a voltage-regulating circuit that uses a reverse-biased Zener diode operating in breakdown to maintain an approximately constant output voltage.
10. What is a transistor voltage regulator? A transistor voltage regulator uses a transistor as a controlling or pass element, usually with a reference and feedback circuit, to maintain a nearly constant output voltage.
14. Descriptive questions for practice
- Draw the block diagram of a regulated DC power supply and explain each stage.
- Explain the operation of a half-wave rectifier with a circuit diagram and output waveform.
- Explain the operation of a centre-tapped full-wave rectifier.
- Explain the operation of a bridge rectifier.
- Compare half-wave and full-wave rectifiers.
- Explain how a capacitor filter reduces ripple.
- Define voltage regulation and derive or apply the percentage load-regulation expression used in your course.
- Explain the operation of a Zener diode as a voltage regulator.
- Explain the basic working principle of a transistor series voltage regulator.
- Compare Zener and transistor voltage regulators.
15. Numerical practice
Use ideal rectifier formulas unless a diode drop or other non-ideal condition is stated.
Problem 1: A half-wave rectifier has an input peak voltage of 20 V. Calculate its average output voltage.
Problem 2: A full-wave rectifier has a peak voltage of 15 V across the complete secondary winding. Calculate its ideal average output voltage.
Problem 3: A full-wave rectifier is supplied from a 60 Hz AC source. Find the ripple frequency.
Problem 4: A capacitor-filtered full-wave rectifier supplies 80 mA to a load. The AC frequency is 50 Hz and the capacitor is 800 µF. Estimate peak-to-peak ripple voltage.
Problem 5: A Zener regulator has \(V_{in}=15\text{ V}\), \(V_Z=6\text{ V}\), \(R_S=450\ \Omega\), and \(R_L=1.5\text{ k}\Omega\). Assuming regulation, calculate \(I_S\), \(I_L\), and \(I_Z\).
Answers for checking
- \(V_{DC}=20/\pi\approx6.37\text{ V}\)
- \(V_{DC}=2(15)/\pi\approx9.55\text{ V}\)
- \(f_r=2(60)=120\text{ Hz}\)
- \(f_r=100\text{ Hz}\), \(C=0.0008\text{ F}\); \(V_{r(pp)}\approx0.08/(100\times0.0008)=1\text{ V}\)
- \(I_S=(15-6)/450=20\text{ mA}\); \(I_L=6/1500=4\text{ mA}\); \(I_Z=16\text{ mA}\)
For Problem 5, check the Zener's specified operating-current and power limits before concluding that regulation is possible.
16. Self-test
- What are the four main stages of a traditional linear power supply?
- Which rectifier uses only one half-cycle?
- Which rectifier produces two output pulses per input cycle?
- What is the ripple frequency of a full-wave rectifier supplied by 50 Hz AC?
- What is the purpose of a capacitor connected across the load?
- What happens to ripple when capacitance increases, all else equal?
- In a Zener regulator, why is a series resistor required?
- How is series current divided in a loaded Zener regulator?
- What is the role of a transistor in a series regulator?
- Why does a linear regulator need to dissipate heat?
Answers
- Transformer, rectifier, filter and voltage regulator.
- Half-wave rectifier.
- Full-wave rectifier.
- 100 Hz.
- To reduce ripple by storing and releasing charge.
- Ripple generally decreases.
- To limit current and protect the Zener diode.
- Between the Zener branch and the load.
- It acts as a controlled pass element.
- It dissipates the excess voltage as power in the pass element.
Chapter summary
- A regulated power supply converts an AC input into a stable DC output.
- A traditional linear supply uses transformer, rectifier, filter and regulator stages.
- A half-wave rectifier uses one half-cycle; a full-wave rectifier uses both.
- Full-wave rectification produces ripple at twice the input frequency.
- A capacitor filter smooths pulsating DC by charging near waveform peaks and discharging into the load between peaks.
- A Zener diode can regulate voltage in reverse breakdown when current is properly limited.
- A transistor series regulator controls the power delivered to the load using a pass transistor and usually a feedback/reference circuit.
Next chapter: Bipolar Junction Transistors (BJT) — NPN and PNP transistors, amplification, switching, configurations, operating point, load line and biasing.